Safety tests on the AiPower GXS7600iRD generator rated the unit a Don’t Buy after failing carbon monoxide shutdown checks in November 2026.
Consumer Reports discovered that two different samples of the inverter generator produced very high levels of carbon monoxide during testing in an enclosed area and failed to shut off. Portable generators create deadly levels of this colorless and odorless gas, making automated sensors vital for safety.
Models featuring an automatic carbon monoxide shutoff system rely on a built-in sensor to detect rising gas concentrations around the machine, triggering a shutdown before levels become lethal. SlashGear reported that the GXS7600iRD unit specifically claims to turn off automatically once it detects dangerous thresholds.
“Every generator in our ratings has successfully shut off when run in an enclosed space, indicating that the CO shutoff mechanism works as intended,” said Paolo Fu, who leads generator testing at Consumer Reports.
“लेकिन this model, the AiPower GXS7600iRD, does not shut off at all—even at high levels,” Fu said.
Neither tested unit shut down when exposed to very high gas concentrations, making it the only generator in recent testing to experience this specific failure. Fu said that advertising a faulty safety mechanism creates a false sense of security, as operators might believe they are safe from poisoning while running the machine.
Following correspondence from the testing publication, AiPower responded to the findings regarding its equipment.
“AiPower takes carbon monoxide safety seriously,” the company told Consumer Reports.
The company said that the GXS7600iRD holds certification from an independent third-party laboratory to the ANSI/PGMA G300 safety standard, which includes shutdown requirements.
“Our goal is to make sure every AiPower generator continues to meet safety standards,” the manufacturer added.
SlashGear reported that A-iPower will investigate the problem at the manufacturing level to ensure the reliability of future automatic carbon monoxide shut-offs. The company explained that this effort will include a thorough examination of the factory where the generators are produced alongside a review of the testing laboratory’s work.
Consumer Reports said that generators should always be operated at least 20 feet away from a home to provide maximum ventilation and safety. However, the publication also pointed out that many people improperly run these machines inside or within attached garages, leading to numerous carbon monoxide-related deaths annually.
Consumer Reports tests portable generators by running them in an enclosed space to verify that built-in carbon monoxide sensors trigger an automatic shutoff before gas concentrations become lethal, a protocol led by Paolo Fu, who heads generator testing at the organization.
Because Consumer Reports purchases products anonymously at retail and accepts no advertising, its safety ratings carry significant market authority, often prompting manufacturer investigations, recalls, or redesigns when critical failures are identified.
While investigating the issue, AiPower initiated a comprehensive engineering review involving the factory and the testing laboratory. The firm also started a complete quality check of all units currently sitting in its inventory.