Clinical Indicators Outperform Composite Indices in Cardiovascular Disease Classification

Cardiovascular disease remains a major global health burden, prompting researchers to test whether clinical indicators or compact metabolic measures better spot the condition.

Existing machine-learning approaches commonly rely on either multidimensional clinical indicators or compact composite anthropometric and metabolic indices, but the comparative performance of these two frameworks remains unclear, Nature reported.

To test them, investigators selected participants aged 20–79 years with available cardiovascular disease status from the National Health and Nutrition Examination Survey. The NHANES 2011–2016 cycles formed the development cohort of 7,391 individuals. This group was split using stratified random sampling into a training set of 5,173 participants and a held-out internal test set of 2,218 participants.

Investigators handled missing values in the development cohort using an iterative random forest-based single-imputation procedure fitted strictly on the training data. Feature selection via the whale optimization algorithm and hyperparameter tuning were similarly restricted to the training data.

Across eight evaluated machine-learning algorithms tested on the same internal test set, the clinical-indicator framework generally achieved higher ROC-AUC, PR-AUC, balanced accuracy, specificity, and Macro-F1 values alongside lower Brier scores than the composite-indicator framework.

Within the original SMOTEENN-based analysis, the clinical-indicator random forest model demonstrated favorable overall classification performance. The system yielded a Brier score of 0.103, a specificity of 0.868, a sensitivity of 0.652, a PR-AUC of 0.309, an accuracy of 0.853, a ROC-AUC of 0.862, a Macro-F1 score of 0.654, and a balanced accuracy of 0.760. Hypertension, high cholesterol, age, and diabetes made the largest overall contributions to the model output.

In a sensitivity analysis using SMOTENC, XGBoost and random forest achieved ROC-AUCs of 0.850 and 0.841, respectively. For complete-case temporal validation, researchers used the NHANES 2017–March 2020 cohort comprising 3,383 participants. Testing on that subsequent subset yielded a ROC-AUC of 0.845, a specificity of 0.849, an accuracy of 0.833, a Brier score of 0.120, a PR-AUC of 0.324, and a sensitivity of 0.643.

Photo of author

Health Desk

Health Desk at Archyde.

Dricus du Plessis: UFC ‘Pissed Off’ at Garry, Matching Him With Killers

Markets Enter Week After Correction; RBI Meet, FPI Flows, Crude Oil in Focus