EPFL Researchers Resolve Cryo-EM Bottleneck With Ultrasonic Vitrification

On November 26, 2026, researchers at École Polytechnique Fédérale de Lausanne reported a physical method to resolve a persistent bottleneck in cryo-electron microscopy.

  • Researchers at EPFL used ultrasonic waves during sample vitrification
  • The technique mitigates protein preferred orientation in cryo-EM
  • Method tested on the 50S ribosomal subunit, C-reactive protein, hemagglutinin

Preferred particle orientation, a frequent problem in cryo-electron microscopy, arises when proteins adsorb to the air-water interface in only a limited number of orientations. This issue can considerably increase the data acquisition time needed to reach a desired resolution.

It can even make it impossible to obtain a reconstruction altogether. To overcome this, the researchers showed that preferred orientation can be mitigated by continuously exciting the sample with ultrasonic waves during vitrification.

Ultrasonic Disruption Mechanism

The EPFL team, led by Dr. Ulrich J. Lorenz, introduced a dynamic acoustic method. It continuously shakes particles away from interfacial boundaries during rapid plunge-freezing.

The technique couples an ultrasonic transducer directly into the vitrification pathway. By driving high-frequency mechanical vibrations through the aqueous film immediately before cryogen immersion, acoustic waves scramble macromolecular orientations. The simple, physical nature of this mechanism should make it applicable to a wide range of proteins and implementable using existing vitrification devices.

Content cover image
Photo: nature.com

The researchers integrated a high-frequency piezo-ceramic transducer into a modified plunge-freezing apparatus based on the Thermo Fisher Vitrobot Mark IV. Aqueous protein droplets were dispensed onto holey carbon copper grids inside a climate-controlled chamber and subjected to single-sided blotting.

The plunging mechanism then transferred the grid to an underlying acoustic chamber positioned 9 millimetres from a SECO SC049 transducer. The device operated at 490 kilohertz driven by a 100-volt square wave, delivering an acoustic intensity of approximately 126 decibels at the grid surface.

Experimental Validation

To benchmark performance, the authors evaluated three distinct macromolecular systems. These systems are characterized by notorious orientation challenges: the 50S ribosomal subunit, human pentameric C-reactive protein, and influenza hemagglutinin. Angular isotropy was quantified using the sampling compensation factor (SCF*), which ranges from 0 to 1, where 1 represents an ideal isotropic distribution.

Target Macromolecule Molecular Mass Control SCF* Ultrasonic SCF*
50S ribosomal subunit 1,340 kDa 0.66 0.83
C-reactive protein (pentamer) 120 kDa 0.80 0.90
Hemagglutinin trimer 170 kDa Severe orientation bias High-resolution isotropic map

Cryo-electron tomographic reconstructions revealed that ultrasonic agitation tripled the concentration of unadsorbed particles suspended within the bulk vitreous ice layer. The measured equilibrium constant for interfacial adsorption decreased by a factor of two. This suppressed the directional artifact streaks that typically degrade maps.

According to Nature, purified samples of the 50S ribosomal subunit were provided by Dr. Bertrand Beckert of the Dubochet Center for Imaging in Lausanne. Hemagglutinin was purchased from MyBioSource and C-reactive protein from Sigma-Aldrich for the study.

Impact on Structural Biology

The structural biology community has highlighted preferred orientation as one of the primary remaining barriers. It prevents automated high-throughput single-particle analysis.

International user facilities, including the Diamond Light Source Electron Bio-Imaging Centre (eBIC) in the United Kingdom, frequently screen hundreds of vitrified grids annually. These grids exhibit high particle density but fail to yield isotropic maps due to unyielding orientation bias.

By contrast, ultrasonic excitation provides a purely physical disruption mechanism. It operates uniformly without modifying buffer chemistry. This fundamentally advances transmission electron microscopy sample preparation. Operating a top-tier 300-kilovolt cryo-transmission electron microscope typically incurs institutional costs between 3,000 and 6,000 dollars per 24-hour collection session.

When screening runs reveal preferred orientation only after automated high-throughput data collection, thousands of dollars in facility fees and computational hours are lost on unresolvable datasets. The study, published in Nature Methods, notes that this physical mechanism should be applicable to a wide range of proteins and implementable using existing vitrification devices.

Because the core excitation hardware comprises standard piezo transducers and radio-frequency signal generators, core facility engineers can adapt existing plunge-freezing systems without replacing complete laboratory workbenches. Commercial instrument manufacturers and cryo-EM preparation vendors are evaluating integrations of ultrasonic modules into next-generation automated vitrification devices.

The Nature article specifies that samples were vitrified with a jet of liquid ethane traveling at about 2.6 m s−1. Ultrasonic waves were applied for about 10 ms before the arrival of the liquid ethane jet.

École Polytechnique Fédérale de Lausanne is a leading public research university in Lausanne, Switzerland, with a primary focus on science, technology, engineering, and mathematics (STEM) fields. As of 2025, EPFL enrolled 14,072 students from over 130 countries, reflecting its highly international environment.

The institution, part of the Swiss Federal Institutes of Technology Domain, has grown rapidly in reputation and size, with more than 13,000 full-time students as of 2023, and includes affiliated research centers and laboratories such as the Dubochet Center for Imaging in Lausanne.

Over the coming twelve months, consortium laboratories plan multi-site validation trials. These trials will cover membrane proteins, asymmetric viral capsid assemblies, and drug-bound kinase targets. They will establish standardized operational parameters, optimizing frequency tuning, acoustic power calibration, and jet synchronization for widespread routine adoption.