A workflow that treats explainability as an engineering tool rather than a visualization step lifted lung-injury classification accuracy by more than 17 percentage points, researchers reported.
Researchers applied latent-space clustering, gradient-weighted class activation mapping (Grad-CAM) and Shapley additive explanations (SHAP) iteratively to two convolutional neural networks — a VGG16 model designated V_r_a and an EfficientNetB4 model designated EN_m_a — trained on a small, noisy histology dataset from a porcine model of acute respiratory distress syndrome.
Audit reveals limited dataset and model instability
The dataset contained only nine to ten whole-slide images per treatment group. Tiles inherited slide-level labels, ignoring spatial heterogeneity, and five annotators using the Silva scoring system showed noticeable inter- and intra-observer variation, creating an imperfect ground truth across low, medium and high damage classes.
Unsupervised clustering of 128-dimensional latent vectors revealed that the VGG16 network’s second cross-validation fold split into subclusters where numerous feature vectors collapsed to zero. In ambiguous medium-damage tiles, model predictions aligned more faithfully with visible histology and therapeutic exposures than with the conflicting manual annotations, the researchers found.

Grad-CAM heatmaps then showed that many tiles in that same fold produced no activation at all. The team traced the cause to the dying ReLU phenomenon, where rectified linear units zeroed out negative inputs and halted gradient flow.
Replacing standard ReLU with Exponential Linear Units and Leaky ReLU restored gradient continuity. Evaluated with McNemar’s test, a LeakyReLU-ReLU configuration in the final layers yielded a net accuracy gain of 17.39 percent over the baseline VGG16, with statistically significant improvements across more than 27 percent of samples.
SHAP attribution maps corroborated the spatial findings. Dense leukocyte clusters, proliferative fibroblasts and alveolar hemorrhage registered high positive Shapley values supporting high-damage decisions, while intact alveolar architecture generated negative values opposing them and empty background scored near zero — evidence the networks were responding to valid morphological biomarkers rather than memorizing artifacts.
Targeted refinements drive gains
Acting on those insights, the researchers systematically altered network depth and fine-tuning protocols. Unfreezing a single convolutional layer in VGG16 produced a 10.05 percent accuracy gain, but unfreezing a second layer caused a 15.66 percent drop due to sparse activation maps. In EfficientNetB4, unfreezing batch normalization layers alone gave a 7.20 percent gain, and 5.57 percent when paired with convolutional unfreezing.
To prevent overfitting on the limited data, the team expanded the training corpus sevenfold using deterministic augmentations — blurred variants with 2×2 and 3×3 kernels and brightness shifts between 0.8 and 1.3.
Adding convolutional attention mechanisms to both architectures yielded further improvements: 7.18 percent for attention-augmented VGG16 and 13.18 percent for attention-modified EfficientNetB4, verified by McNemar’s testing with bootstrap confidence intervals. Attention maps concentrated weight on invasive inflammatory clusters and collapsed airspaces at tissue boundaries, though a slight trade-off appeared in the intermediate damage class.
Transformer comparison reveals evaluation nuance
Vision Transformer variants ViT-Tiny and ViT-Small, adapted from binary cancer classification to three-class pulmonary scoring, were also tested. ViT-Tiny reached the study’s highest overall metrics — 86.75 percent accuracy and an F1 score of 0.86 — outperforming ViT-Small and the attention-equipped convolutional networks.
However, the authors noted a methodological nuance: the transformer protocol used a cross-validation structure that randomly dispersed individual tiles across folds, rather than isolating all sections from a single animal into designated folds.
When convolutional attention networks were trained under the same randomized tile distribution, their accuracy scores similarly increased, indicating that tile distribution influenced nominal evaluation metrics. Qualitative inspection also showed ViT-Tiny attention maps were diffuse and lacked the immediate histological correspondence seen in convolutional attention maps.
“Explainability methods can bridge the persistent gap between technical transparency and clinical utility by converting algorithmic explanations into actionable model improvements,” the research team wrote in the paper.
Related reading
- Wired Names ESR Geo Wallet Stand Top MagSafe Pick; Flags Apple FineWoven, Ohsnap!
- Microsoft November Windows Updates Cause NTLM Login Failures for Third-Party Tools
- Tariffs Added 2.9 Points to Goods Inflation, About 0.6 to All Prices (daybreakwire.com)
- Iowa Hawkeyes Favored by 3.5 Points Over Nebraska Cornhuskers for Black Friday Game (news-usa.today)