High-Flux High-Harmonic Generation at 13.5 Nm Driven by Sub-20-fs Green Laser Pulses

Researchers have generated bright extreme-ultraviolet harmonics at 13.5 nanometers using visible green laser light, producing a photon flux exceeding 1011 photons per second per electronvolt and surpassing previous conversion efficiencies by more than an order of magnitude.

The experiment, detailed this week in Nature, marks the first demonstration of high-harmonic generation (HHG) driven by 516-nanometer pulses reaching the lithography-relevant wavelength with microjoule-level energy. The team, led by scientists at the Max Born Institute and the Helmholtz-Zentrum Berlin, converted ytterbium-laser output to green via second-harmonic generation, broadened the spectrum in a gas-filled multipass cell, and compressed pulses below 20 femtoseconds.

“The stabilized intensity we observe is on the scale of the barrier-suppression intensity of helium,” the authors wrote in the paper. “Plasma-core guiding therefore naturally supports ionization conditions compatible with phase-matched HHG.”

Focusing the green driver to a vacuum intensity of roughly 4.5 PW cm−2 — six times the conventional phase-matching limit — the researchers positioned a helium gas jet 0.8 Rayleigh lengths in front of the geometrical focus. Plasma formation immediately defocused the beam, capping the on-axis intensity at approximately 2 PW cm−2 and creating a transversely flattened, self-guided channel that persisted over an extended propagation distance.

Plasma lens stabilizes driving intensity

Simulations confirmed that the plasma-induced defocusing balances the converging wavefront, stabilizing the driving intensity near 0.9 PW cm−2. This self-regulation emerges from the ionization fraction itself: as free electrons accumulate, their negative lensing counters the geometric focus, flattening the wavefront and arresting further intensity growth.

Shorter driving wavelengths reach this stabilized regime at higher intensities than infrared drivers, directly boosting single-atom dipole response and macroscopic conversion efficiency. The paper notes that the pressure required for phase matching scales approximately as λ2, meaning the green driver operates at lower gas densities than mid-infrared systems, reducing plasma defocusing and preserving the high regulated intensity.

Blueshift multiplies across harmonic orders

The measured driving spectrum after the interaction shows a pronounced blueshift, a hallmark of strong laser-plasma interaction. Through HHG, this shift multiplies by the harmonic order — 37 in this case — moving HH37 from the expected 88.9 eV to the measured 91.8 eV (13.5 nm), squarely inside the 2% bandwidth window required for extreme-ultraviolet lithography.

At the peak particle density of 6.2 × 1019 cm−3, the absorption length for 13.5-nm radiation in helium is 308 μm. The harmonic flux grows monotonically across roughly two absorption lengths, indicating operation near the absorption-limited regime. The 37th harmonic delivers 2.7 μW within the lithography bandwidth; the 33rd harmonic reaches 7.3 μW over its full linewidth, corresponding to a conversion efficiency of 10−6.

Phase matching recovered in the self-regulated channel

Coherence-length analysis reveals that phase matching is not instantaneous. In the initial gas region, rapid intensity drop and strong blueshift modulate the dipole amplitude, preventing long coherence lengths. Once the driver enters the stabilized regime, dipole emission becomes nearly stationary and overlaps with an extended region of long coherence length, enabling macroscopic buildup.

The spectrally filtered HH37 emission centers at t = −12 fs relative to the reshaped pulse peak. At that instant the spatially averaged ionization fraction reaches the critical value of approximately 1.2%, matching the conventional balance between neutral-atom and plasma dispersion. The intrinsic dipole phase contributes only a minor correction, confirming that the self-regulated channel restores textbook phase-matching conditions despite the violent initial reshaping.

Why green changes the scaling laws

Conventional HHG sources for 13.5 nm have relied on 800-nm Ti:sapphire or longer-wavelength optical parametric amplifiers. Scaling to shorter drivers flips two critical dependencies: the single-atom cutoff scales as λ−2, demanding higher intensity for the same photon energy, but the phase-matching pressure scales as λ2, lowering the required density and thus the plasma defocusing.

The experiment demonstrates that the second effect dominates. By operating at 516 nm, the team accessed the high-intensity, low-density corner of parameter space where plasma-core guiding stabilizes the driver at intensities that would be unattainable in higher-pressure, longer-wavelength geometries.

Path toward a compact EUV source

Ytterbium-based lasers offer high average power, high repetition rate, and industrial-grade reliability — attributes that have eluded Ti:sapphire and OPA systems. Converting their fundamental output to green and driving HHG in a gas jet preserves those advantages while reaching the flux levels required for metrology and resist development.

The reported flux of 2.7 μW in-band at 1 kHz repetition rate corresponds to 2.7 nJ per pulse. Scaling to 100 kHz — routine for modern ytterbium amplifiers — would yield 270 μW average power, approaching the needs of actinic inspection tools.

Next steps include extending the interaction length with waveguides or hollow-core fibers to boost flux further, and characterizing the temporal coherence of the harmonic comb for attosecond metrology. The team has not yet disclosed a timeline for a prototype source, but the physics validation is now on the record.

“Plasma-core guiding naturally supports ionization conditions compatible with phase-matched HHG,” the authors conclude in Nature. “Shorter driving wavelengths establish these conditions at higher regulated intensities and thereby favor higher conversion efficiency.”

Photo of author

Technology Desk

Technology Desk at Archyde.

Strawberry Fields Festival Lightning Strike Hospitalises Four

Docket Commenters Call for Flexibility in Rare Disease Trial Design and Evidence, but Question